AirPure Technologies helps facility managers and HVAC engineers select, configure, and maintain precision air treatment equipment that protects processes, products, and people.
From compact fan coil units to large-scale custom AHU systems, we engineer air treatment equipment matched to your exact airflow, humidity, and filtration requirements.
Custom-configured modular AHUs for ventilation, heating, cooling, humidification, and filtration. Airflow capacities from 1,000 to 150,000 m3/h with Eurovent-certified performance. Available with direct expansion (DX) or chilled water coils, enthalpy recovery wheels, and EC fan motors rated to SFP Class 1-4.
Request Specifications
Desiccant and refrigerant-based dehumidification systems achieving dew points as low as -40°C. Designed for pharmaceutical, food processing, and lithium battery manufacturing.
Request Specifications
Compressed air and process air drying systems using refrigerated, desiccant, and membrane technologies. Achieving ISO 8573-1 Class 1-4 air quality with pressure dew points from +3°C to -70°C. Energy-optimized cycling controls reduce compressor energy waste by 15-25%.
Request Specifications
Ceiling, floor, and wall-mounted fan coil units with EC motor technology (IE5 class) for quiet zone climate control. Sound pressure levels from 28 dB(A) in low-speed mode. 2-pipe and 4-pipe configurations with variable air volume (VAV) capability.
Request Specifications
High-velocity air curtain barriers for loading docks, cold storage entrances, and commercial doorways. Maintains indoor climate separation while allowing unrestricted passage.
Request Specifications
HEPA H13/H14 and ULPA U15/U16 filtration modules, activated carbon adsorption stages, and ePM1/ePM2.5 pre-filter assemblies. Tested per ISO 16890 and EN 1822. Standalone purification units or AHU-integrated configurations with DOP/PAO leak-tested frames.
Request Specifications
Every AirPure system is engineered to minimize energy consumption while maximizing air quality performance. Our heat recovery wheels reclaim up to 85% of exhaust air thermal energy, and EC fan technology reduces motor power consumption by 30-50% compared to AC drives.
Our air treatment systems are engineered for the unique air quality, humidity, and temperature demands of these critical sectors.
GMP-compliant air handling for cleanrooms, labs, and sterile production environments. ISO Class 5-8 filtration with precise humidity and pressure cascade control.
HACCP-compatible air treatment systems for temperature-controlled production zones, drying tunnels, and cold storage areas. Preventing condensation and microbial contamination.
Precision air handling and free cooling systems for server halls. Maintaining 18-27°C and 40-60% RH per ASHRAE TC 9.9 guidelines with maximum PUE efficiency.
Comfort ventilation and humidity management for offices, hotels, hospitals, and retail spaces. Balancing indoor air quality with energy performance targets.
Air curtains, dehumidification, and climate control for cold storage entrances, loading docks, and refrigerated warehouses. Preventing energy loss and frost buildup.
Process air drying, fume extraction, and factory ventilation systems for automotive, electronics, printing, and chemical manufacturing operations.
Answers to common questions from facility managers and HVAC engineers evaluating air treatment systems.
AHU sizing depends on your required airflow rate (m3/h or CFM), heating/cooling loads, humidity targets, and filtration class. Our application engineers perform a load calculation based on your facility drawings and process requirements to recommend the optimal configuration. Typical commercial buildings require 6-10 air changes per hour; pharmaceutical cleanrooms may require 20-60 ACH.
Refrigerant-based systems are cost-effective when target humidity is above 45% RH and ambient temperatures are moderate. Desiccant systems are essential when you need dew points below 10°C or when operating in cold environments where refrigerant coils would frost. Many applications benefit from a hybrid approach combining both technologies.
Our AHU and dehumidification systems carry Eurovent Certified Performance, CE Marking, UL Listed, ISO 9001, ISO 14001, and AHRI Certification depending on the product line and target market. We provide full documentation with every shipment.
Standard modular AHU configurations ship within 6-8 weeks. Fully custom units with specialized coatings, unusual dimensions, or atypical filter configurations typically require 10-14 weeks. We maintain buffer stock of common components to accelerate delivery for urgent projects.
Yes. Our service network covers 85+ countries with 45 regional service centers. We offer full commissioning, preventive maintenance agreements, filter replacement programs, and 24/7 emergency support for critical-environment clients. Remote monitoring packages are available for real-time system health tracking.
Our rotary heat exchangers recover up to 85% of thermal energy from exhaust air, reducing the heating/cooling load on fresh supply air by a measurable margin. In temperate climates with 4,000+ heating degree days, this translates to 25-40% reduction in HVAC energy costs. The payback period is typically 18-30 months depending on local energy prices and annual operating hours.
Our application engineering team will review your facility requirements, recommend the optimal system configuration, and provide a detailed quotation — typically within 3 business days.